• Microwave Emc Anechoic Chamber 14KHz To 40GHz 100dB For Data Security rf shielding room emc anechoic chamber
  • Microwave Emc Anechoic Chamber 14KHz To 40GHz 100dB For Data Security rf shielding room emc anechoic chamber
  • Microwave Emc Anechoic Chamber 14KHz To 40GHz 100dB For Data Security rf shielding room emc anechoic chamber
  • Microwave Emc Anechoic Chamber 14KHz To 40GHz 100dB For Data Security rf shielding room emc anechoic chamber
  • Microwave Emc Anechoic Chamber 14KHz To 40GHz 100dB For Data Security rf shielding room emc anechoic chamber
  • Microwave Emc Anechoic Chamber 14KHz To 40GHz 100dB For Data Security rf shielding room emc anechoic chamber
  • Microwave Emc Anechoic Chamber 14KHz To 40GHz 100dB For Data Security rf shielding room emc anechoic chamber
  • Microwave Emc Anechoic Chamber 14KHz To 40GHz 100dB For Data Security rf shielding room emc anechoic chamber
  • Microwave Emc Anechoic Chamber 14KHz To 40GHz 100dB For Data Security rf shielding room emc anechoic chamber
  • Microwave Emc Anechoic Chamber 14KHz To 40GHz 100dB For Data Security rf shielding room emc anechoic chamber
  • Microwave Emc Anechoic Chamber 14KHz To 40GHz 100dB For Data Security rf shielding room emc anechoic chamber
  • Microwave Emc Anechoic Chamber 14KHz To 40GHz 100dB For Data Security rf shielding room emc anechoic chamber

Microwave Emc Anechoic Chamber 14KHz To 40GHz 100dB For Data Security rf shielding room emc anechoic chamber

High Light
Microwave Anechoic Chamber, Fully Anechoic Chamber, Fully Anechoic Room
Type
RC Filter
Transfer Function
Low Pass
Package Type
Surface Mount
Nominal Center Frequency
50Hz
3dB Bandwidth
10M
Insertion Loss
100dB
Input Impedance
50oHm
Stopband Attenuation
100dB
Power Supply
Single Phase Three Phase Or Dc
Usage
Emc Test
Room Size
Customized
Door Size
Customized
Panel
2mm/3mm Steel Panel
Attenuation
14KHz-40GHz >=100dB
Packing
Wooden Case
Delivery Time
2-3weeks For Emc Testing Electromagnetic Shielding RF Room
Port
Shanghai
Brand Name
haozhuo
Certification
CE RoHS
Model Number
H
Minimum Order Quantity
>=1 Sets
Price
$10,000.00
Packaging Details
wooden case
Supply Ability
1 Set/Sets per Month
$10000.00

Description

Targeted Electromagnetic Shielding for Secure Testing Environments
Our Microwave EMC Anechoic Chamber is purpose-built for laboratories and test facilities requiring stringent electromagnetic isolation from 14 kHz to 40 GHz. It serves engineering teams focused on compliance and data security by providing a stable, low-noise shielded enclosure. Developed in collaboration with leading emi filter manufacturers and rf shield box manufacturers, the chamber accommodates various configurations, including customizable panel thickness and door sizes, enabling precise adaptation to specific experimental setups and target equipment under test.

Advanced Design and Measurable Shielding Performance
Constructed with 2 mm or 3 mm galvanized steel panels, the chamber achieves attenuation levels of at least 100 dB across a broad frequency range, with up to 110 dB in targeted sub-bands. The ventilated cellular wave-guide window enables controlled airflow while minimizing RF leakage. Optional electromotive or automatic shielding doors integrate power line filters for further EMI suppression, enhancing isolation integrity. This integration with specialized power line filter manufacturers and use of high-performance absorbers ensures accurate and repeatable measurements in both EMC and EMI testing protocols.

Industry Applications in EMC Compliance and Data Security
This chamber enables comprehensive verification of shielding effectiveness and EMI control across industries such as telecommunications, defense, and high-frequency microwave product manufacturing. Users benefit from a controlled environment that supports EMI/EMC testing, equipment validation, and shielding system commissioning. The chamber’s adaptability complements workflows requiring compliance with international standards, aiding 3 phase emi filter manufacturer solutions and rfi line filter suppliers in meeting performance demands for secure and reliable electronic system integration.


Product Advantages

Structural and System Design Superiority
Our EMC Anechoic Chamber incorporates modular design with scalable panel sizes, allowing integration into various facility configurations. The robust galvanized steel construction, combined with precision-engineered shielding doors, facilitates effective RF sealing. Integration with industry-recognized emi filter company components, such as specialized rfi line filter suppliers for power entry points, enhances system compatibility and reduces electromagnetic leakage risks. The cellular wave-guide window maintains ventilation without compromising shielding integrity, showcasing a balanced structural approach to functionality and adaptability.

Enhanced Performance and User-Centered Usability
This chamber delivers consistent attenuation above 100 dB, ensuring reliable noise suppression across a wide frequency spectrum. Power filters and RF absorbers are integrated seamlessly, enabling users to achieve compliance with stringent EMC standards efficiently. Its configurability supports diverse test scenarios, reducing setup complexity and operational downtime. The product offers technical teams an optimal balance of shielding performance and operational convenience, backed by our expertise as a trusted emi filter manufacturer. This results in minimized interference and maximized test accuracy, critical to rigorous data security and EMC validation processes.


Use Scenarios

EMC Compliance Testing in Telecommunications Environments
In telecom manufacturing and R&D, maintaining electromagnetic compatibility is critical to product functionality and regulatory approval. This chamber provides an isolated environment where engineers test devices against EM disturbances from 14 kHz to 40 GHz. By integrating with single phase emi filter manufacturers solutions and power line filters, it assures testing accuracy for base stations, RF modules, and communication equipment. The chamber’s shielding performance directly supports workflows that demand repeatable, high-fidelity EMI measurements, enabling compliance verification and minimizing signal interference risks in deployment environments.

Secure Data Verification in Microwave and RF Laboratories
Data security facilities handling sensitive microwave and RF device testing benefit significantly from this chamber’s extensive frequency attenuation capabilities. The product supports validation of shielding effectiveness in environments requiring minimal electromagnetic leakage, crucial for defense, aerospace, and secure communications sectors. By collaborating closely with industrial filter manufacturers and using advanced low pass filter integration, the chamber ensures the testing environment meets exacting emission shielding standards. Its adaptability also facilitates calibration and acceptance testing of RF measurement systems under controlled, low-noise conditions.


14KHz-40GHz more than 100dB for data/voice security EMI anechoic chamber

 

When a shielded room is necessary?

· If your lab is near a broad spectrum emitter (i.e equipment that transmits multiple frequencies under 400Hz), radio tower, mobile phone transmitter or other large field generators, then you should consider a shielded room.

· If your research is in the gamma band and you do not want to use a 60/50Hz notch filter to remove mains power noise, you might consider a shielded room. We recommend taking the steps above to first minimize the mains power noise. If that is not sufficient for your needs, then a shielded room may help. 

 

Product Features

Shielding panels are made of molded cold-rolled steel plates. They are jointed in way and welded with CO2 protection, which can restrain the plates from distortion and ensure the leveling of the steel plates.

Self-supported frame construction is made of section materials.

Shielding door is optional: standard electromotive door (electromotive / manual alternative), full-automatic shielding door (light-activated with password) sliding door. Subshining stainless steel decoration is on surface of the door. Standard dimension of the door is:0.85×2(m).

Large-scale hanging sliding shielding-door, electromotive sliding push-in door, electromotive sliding gasbag door, rotated door with track.

Ventilated window is designed in cellular wave-guide type with dimension:300×300(mm).

Power filter is in condition of high-performance and low-leakage.

Telephone, air-conditioning, fire-fight devices, optical fiber and CAT5 cables can be equipped customized.

Decoration will be arranged in the shielding room according to standard equipment room requirements.

Shielding Properties (dB)

 

Magnetic field

14kHz

85dB

100KHz

100dB

200KHz

110dB

Plane wave

50-103MHz

120dB

 

Microware

1-10GHz

110dB

10-20GHz

100dB

20-40GHz

80dB

Application Scope

EMC tesing

Items 1

Module Panel type, 2mm/3mm galvanized steel plate

 

Items 2

RF Shielding Door, Open size:1000*2000mm
Or Customized dimension

 

Items 3

Power Filters
16A/ 32A/50A/63A
Or Customized parameter

 

Items 4

Honeycomb Ventilation panels 
300x300x25mm
300x600x25mm
Or Customized dimension

 

Items 5

RF Panel
300*200mm,including waveguide Ø4cm / L220cm x1 BNC*2/N*2/SMA*2
Or Customized dimension

 

Items 6

Floor
Anti-static floor or Laminate flooring
Or customized materials

 

Items 7

Foam RF absorber
Ferrite tile
High power absorber

 

Items 8

Beryllium copper Fingers

 

Items 9

Steel waveguide

 

Items 10

EMI Shielding Gasket

 

 

 

RF Anechoic chamber Shielding Properties (dB)

 

Magnetic field

14kHz 75dB
100KHz 100dB
200KHz 110dB
Plane wave 50-103MHz 120dB

 

Microware

1-10GHz 110dB
10-20GHz

100dB

 




Before-sale:
1.All inquires will be replied with 8 hours. 7D/24H service,Please feel free to contact us with Email/TM/Skype.  
2.Strong technical team and Professional sales.  
3.Customized packaging is acceptable.  
4.Welcom customers from all the world to visit our factory.  

After-sale:
1.All emi filter will be tested and adjusted before shipping.  
2.After receiving the products,Any question we will try our best to solve.

1. How do I pay for my purchase order?

We can accept following payment method: T/T, L/C, D/A, D/P, and we also can accept Westernunion,Paypal.If you want another payment please contact us.

2. Is there a tracking number for my item?

Yes, of course. We usually ship your goods by EMS, DHL, Fedex, UPS, TNT with online track, you can view the ship status on website.

3. Could you do OEM for us?

Sure,we accept OEM order,please provide us the label picture.

4. How does your factory do related quality control?

Quality is top priority. We attach great importance to quality control from the very beginning of manufacturing

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
Name
Email*
Message
Verification Code*
Verification Code
Leave a message
Name
Email*
Message
Verification Code*
Verification Code