• Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber
  • Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber
  • Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber
  • Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber
  • Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber
  • Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber
  • Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber
  • Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber
  • Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber
  • Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber
  • Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber
  • Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber

Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber


High Light
rf anechoic chamber, Anechoic Test Chamber, Electromagnetic Anechoic Chamber
Type
RC Filter
Transfer Function
Low Pass
Package Type
Surface Mount
Nominal Center Frequency
50Hz
3dB Bandwidth
10M
Insertion Loss
100dB
Input Impedance
50oHm
Stopband Attenuation
100dB
Power Supply
Single Phase Three Phase Or Dc
Usage
Emc Test
Room Size
Customized
Door Size
Customized
Panel
2mm/3mm Steel Panel
Attenuation
14KHz-40GHz >=100dB
Packing
Wooden Case
Delivery Time
2-3weeks For Emc Testing Electromagnetic Shielding RF Room
Port
Shanghai
Brand Name
haozhuo
Certification
CE RoHS
Model Number
H
Minimum Order Quantity
>=1 Sets
Price
$10,000.00
Packaging Details
wooden case

Description

Advanced EMC Testing Environment for Specialized Applications
This chamber is engineered to meet the stringent needs of engineers, researchers, and quality assurance teams requiring precise electromagnetic compatibility (EMC) testing up to 40 GHz. Developed by experienced emi filter manufacturers, it delivers a controlled low-reflection setting for accurate radiated and conducted emissions measurement. The solution integrates RF absorbers and shielding panels, making it suitable for test labs demanding superior environmental control to evaluate RF transceivers, microwave devices, and wireless modules with high reliability and repeatability.

Robust Technical Construction and Shielding Performance Metrics
Utilizing molded cold-rolled steel shielding panels with CO2 welding, the chamber ensures structural durability and minimal distortion. The shielding system achieves over 100 dB attenuation spanning 14 kHz to 40 GHz, verified across multiple frequency bands including magnetic fields and microwave ranges. Components such as ventilated cellular wave-guide windows and customizable power line filters from power line filter manufacturers enable continuous airflow without compromising shielding integrity. Additional features include anti-static flooring and optional electromotive or automatic doors, enhancing safety and operational flexibility during testing.

Integration into Industrial and Research EMC Applications
This chamber is widely applied in manufacturing quality control for RF-enabled products, R&D for microwave device development, and pre-compliance testing environments. Its modular design and configuration flexibility support integration into diverse laboratory setups, including floor-pit installations. As a product engineered with input from leading rfi line filter suppliers and emi filter companies, it facilitates compliance with industry standards, stabilizes test results against external interference, and supports accelerated product development lifecycles in telecommunications, aerospace, medical devices, and industrial automation sectors.


Product Advantages

Design Features Supporting Modular Flexibility and Shielding Efficiency
The test chamber features modular, cold-rolled galvanized steel panels combined with precise CO2 welding, ensuring both robustness and minimal electromagnetic leakage. Its design incorporates customizable dimensions and door configurations crafted by leading rf shield box manufacturers, allowing adaptation to various laboratory layouts. Ventilated cellular wave-guide windows facilitate controlled airflow while maintaining shielding effectiveness. Integrated power line filters sourced from established emi filter manufacturers enhance internal noise suppression without compromising structural integrity, optimizing the EMC test environment architecture.

Operational Excellence Enhancing Test Accuracy and User Capability
With attenuation exceeding 100 dB across key frequency bands, this chamber significantly reduces ambient RF noise, enabling high-fidelity measurement of electromagnetic emissions. Optional automatic or electromotive shielding doors provide convenience and safety, reducing manual handling risks during high-frequency test cycles. The inclusion of anti-static or laminate flooring improves operational safety, especially in sensitive electromagnetic scenarios. This engineered solution from an emi filter company supports seamless integration into existing workflows while meeting strict compliance requirements, thereby improving test throughput and product validation confidence.


Use Scenarios

High-Frequency EMC Testing in Advanced Telecommunications Development
In telecom R&D laboratories developing next-generation wireless communication modules, this chamber serves as a dedicated environment for radiated and conducted emission evaluation. The high attenuation specification, combined with integrated power line filters from power line filter manufacturers, ensures minimal external RF interference, critical for validating antenna designs and transceiver shielding. Its flexible door options and customizable size allow incorporation into complex test setups, supporting multiple device configurations and enabling efficient measurement cycles essential for accelerated product innovation and compliance certification.

RF Shielded Environment for Medical Device Compliance Verification
Within the medical device manufacturing sector, stringent EMC standards necessitate reliable testing of RF emission from diagnostic and therapeutic equipment. This chamber, developed in close collaboration with emi filter manufacturers, offers an optimized low-reflection space with ferrite tile and absorber-lined walls to handle sensitive, high-power RF signals typical in medical applications. Its controllable environment supports verification of shielding effectiveness important for patient safety and regulatory compliance, integrating easily into controlled laboratory workflows to ensure repeatable and auditable test results aligned with international EMC regulations.



up to 40GHz High Performance EMC Testing Chamber

 

Upon request, RF shielded rooms can be lined with plasterboard walls and a suspended ceiling. The floor of the shield room can be constructed using wood with a vinyl topping flush to the door threshold. In a control room or data center, the floor can be constructed as a raised computer floor to enable easy cable routing. The raised computer floor is constructed using standard anti-static floor tiles onto adjustable pedestals in order to withstand a minimum average floor load of 500 kg/m2. A raised computer floor system provides a flush and threshold-less entrance to the control or amplifier room when the chamber is built inside a floor pit.

 
When a shielded room is necessary?
· If your lab is near a broad spectrum emitter (i.e equipment that transmits multiple frequencies under 400Hz), radio tower, mobile phone transmitter or other large field generators, then you should consider a shielded room.
· If your research is in the gamma band and you do not want to use a 60/50Hz notch filter to remove mains power noise, you might consider a shielded room. We recommend taking the steps above to first minimize the mains power noise. If that is not sufficient for your needs, then a shielded room may help.
 

Product Features
Shielding panels are made of molded cold-rolled steel plates. They are jointed in way and welded with CO2 protection, which can restrain the plates from distortion and ensure the leveling of the steel plates.
Self-supported frame construction is made of section materials.
Shielding door is optional: standard electromotive door (electromotive / manual alternative), full-automatic shielding door (light-activated with password) sliding door. Subshining stainless steel decoration is on surface of the door. Standard dimension of the door is:0.85×2(m).
Large-scale hanging sliding shielding-door, electromotive sliding push-in door, electromotive sliding gasbag door, rotated door with track.
Ventilated window is designed in cellular wave-guide type with dimension:300×300(mm).
Power filter is in condition of high-performance and low-leakage.
Telephone, air-conditioning, fire-fight devices, optical fiber and CAT5 cables can be equipped customized.
Decoration will be arranged in the shielding room according to standard equipment room requirements.
Shielding Properties (dB)

 
Magnetic field

14kHz 85dB
100KHz 100dB
200KHz 110dB
Plane wave 50-103MHz 120dB

 
Microware

1-10GHz 110dB
10-20GHz 100dB
20-40GHz 80dB
Application Scope
EMC tesing
Items 1 Module Panel type, 2mm/3mm galvanized steel plate  
Items 2 RF Shielding Door, Open size:1000*2000mm
Or Customized dimension
 
Items 3 Power Filters
16A/ 32A/50A/63A
Or Customized parameter
 
Items 4 Honeycomb Ventilation panels
300x300x25mm
300x600x25mm
Or Customized dimension
 
Items 5 RF Panel
300*200mm,including waveguide Ø4cm / L220cm x1 BNC*2/N*2/SMA*2
Or Customized dimension
 
Items 6 Floor
Anti-static floor or Laminate flooring
Or customized materials
 
Items 7 Foam RF absorber
Ferrite tile
High power absorber
 
Items 8 Beryllium copper Fingers  
Items 9 Steel waveguide  
Items 10 EMI Shielding Gasket  

 
 

RF Anechoic chamber Shielding Properties (dB)

 
Magnetic field

14kHz 75dB
100KHz 100dB
200KHz 110dB
Plane wave 50-103MHz 120dB

 
Microware

1-10GHz 110dB
10-20GHz

100dB

 



Before-sale:
1.All inquires will be replied with 8 hours. 7D/24H service,Please feel free to contact us with Email/TM/Skype.  
2.Strong technical team and Professional sales.  
3.Customized packaging is acceptable.  
4.Welcom customers from all the world to visit our factory.  

After-sale:
1.All emi filter will be tested and adjusted before shipping.  
2.After receiving the products,Any question we will try our best to solve.

1. How do I pay for my purchase order?

We can accept following payment method: T/T, L/C, D/A, D/P, and we also can accept Westernunion,Paypal.If you want another payment please contact us.

2. Is there a tracking number for my item?

Yes, of course. We usually ship your goods by EMS, DHL, Fedex, UPS, TNT with online track, you can view the ship status on website.

3. Could you do OEM for us?

Sure,we accept OEM order,please provide us the label picture.

4. How does your factory do related quality control?

Quality is top priority. We attach great importance to quality control from the very beginning of manufacturing

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
Name
Email*
Message
Verification Code*
Verification Code
Leave a message
Name
Email*
Message
Verification Code*
Verification Code